Fire Fighting Equipment

Dry Riser Outlet Cabinets & System

PART NUMBER:10905601
MATERIAL:16SWG ZINTEC STEEL
FINISH:RED RAL3002
BACK BOX DIMENSIONS:
For cabinet dimensions please consult factory

PART NUMBER:10905602
MATERIAL:16SWG ST. STEEL
SATIN POLISHED
BACK BOX DIMENSIONS:
For cabinet dimensions please consult factory

Dry riser gate valves act as outlets from the riser main. These valves are situated on each floor of the high rise building and are normally housed in outlet cabinets which are manufactured to BS5041 part 4. Dry riser gate valves come complete with inlets flanged 65mm BS4504 PN16, 2.5”BS10 table D and screwed 2.5” BSPT, outlets to BS336, complete with blank cap and chain, strap and padlock, complying to BS5041 part 2. To the top of riser should be fitted with an air release valve which releases all air from the riser, as water is pumped in, but closes automatically under pressure of water. A 1” drain valve can be used at the bottom of the riser if the pipe work goes below the inlet breeching valve, so the system can be completely drained. RECOMENDED MOUNTING 750mm FROM FLOOR TO VALVE CENTRE.




Landon Kingsway Dry Riser Cabinet

Landon Kingsway Dry Riser Cabinet

Dry Riser Inlet Cabinets & System

PART NUMBER:10905502
DRY RISER INLET VERTICAL
MATERIAL:16SWG ZINTEC STEEL
FINISH:RED RAL3002
BACK BOX DIMENSIONS:
For cabinet dimensions please consult factory


PART NUMBER:10905506
DRY RISER INLET VERTICAL
MATERIAL:16SWG ST. STEEL
SATIN POLISHED

BACK BOX DIMENSIONS:
For cabinet dimensions please consult factory


An inlet breeching at ground level provides the connection to the water supply. The system is normally dry and is charged by the fire brigade in an emergency. Breeching inlets have either 2 or 4 inlet connections complete with 2.5” male instantaneous inlets to BS336 fitted with non-return valves, 1” drain valve and caps and chains. A 100mm (4”) rising main uses a 2-way inlet breeching in a vertical or horizontal position. A 150mm (6”) rising main uses a 4-Way inlet breeching. Inlet Breechings comply with the requirements of BS 5041 Part 3.
The Breechings are normally housed in inlet cabinets, normally recessed into the external wall of the building in a vertical or horizontal position, 4 -way breechings in a square inlet breeching cabinet, manufactured in accordance with BS 5041 Part 5. Cabinets for foam inlets are available on request. RECOMENDED MOUNTING 750mm FROM FLOOR TO VALVE CENTRE             


Landon Kingsway Dry Riser Cabinet

Landon Kingsway Dry Riser Cabinet